Generator Set PK 1100 KVA
Generator Set PK 1100 KVA

Generator Set PK 1100 KVA

Tecnics Carpi generator sets provide optimum performance and reliability for stationary standby, prime power and continuous duty applications. All generator sets are built in our factory and production tested.

716PK1100
Information Request

Information Request

Generator Set PK 1100 KVA

Generator Set PK 1100 KVA


Tecnics Carpi generator sets provide optimum performance and reliability for stationary standby, prime power and continuous duty applications. All generator sets are built in our factory and production tested.

Please fill up below informations. System will send price for requested product immediately to email address provided.

* Required fields

Cancel or 

Description

Our generator sets are "CE" marked and each one is supplied with the corresponding Declaration of Conformity, which covers the following standards and directives:

  • 2006/42/EC, on the safety of machinery.
  • 2005/88/EC, on noise emissions in the environment by machinery for outdoor use.
  • 2004/108/EC, on electromagnetic compatibility.
  • 2006/95/EC, on the electrical safety of electrical equipment with voltage limits.
  • EN61326/2006, on electromagnetic compatibility tests.
  • EN12601-1:2010, on the electrical safety testing of electrical panels.
  • EN12601-1:2010, on electrical safety testing through the defined generator.
  • ISO 8528- ISO 3046, on the power of the unit, with barometric reference 100kPa, 25ºC and 30% relative humidity

VOLTAGE STANDBY RATING (ESP) PRIME RATING (PRP) STAND-BY AMPER
kVA kW kVA

kW

400/231 1100 880 1000 800 1587.76

STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.

The genset is factory tested before delivery. Voltage, frequency and load tests are carried out, as well as tests of the correct operation of the engine, oil and temperature alarms with their shutdown effect.

Product Details

Manufacturer
TECNICS GE
Model
PK1100E
Engine Brand and Model
PERKINS - 4008TAG2A
AC Alternator Brand and Model
ECO43-1LN
Control Unit
HGM 9510 EN SINCRONIZACION
SMARTGEN - HGM7210
Protection Breaker
1600 A
Motorized Switching
Optional
Overall Dimensions (Lenght x Width x Height) (mm)
5050 x 1880 x 2400 - OPEN FRAME CHASIS
CONTENEDOR 20 PIES - SOUNDPROOF CHASIS
Acustic Sound Level (soundproof models)
68 dB (A) @ 7m and 75% load

Reviews (0)

No reviews
Product added to wishlist
Product added to compare.